Diethyl Telluride Chemical Storage Specifications

Compliant storage and rental solutions for Diethyl Telluride (C2H6Te). EPA, OSHA, and NFPA guidance for containment, segregation, and fire protection — with rental buildings matched to this material.

Flammable hazardFlammable Storage

Chemical formula

About Diethyl Telluride

some fungi and bacteria (Penicillium brevicaule, P. chrysogenum, and P. notatum and the bacterium Pseudomonas fluorescens).[5] The toxicity of DMTe is unclear. It is produced by the body when tellurium or one of its compounds are ingested. It is noticeable by the garlic smelling breath it gives those exposed, similar to the effect of DMSO. Tellurium is known to be toxic.[6]

Structured hazard data

Hazard class
See SDS
Storage category
Flammable Storage
Flammable
Yes
Flash point
42 C
Storage temperature
See SDS
Recommended extinguishing agent
Water
Compatibility / segregation
Strong oxidizing agents.

Flammable liquids (Category 3), H226 Acute toxicity, Oral (Category 3), H301 Acute toxicity, Inhalation (Category 3), H331 Acute toxicity, Dermal (Category 3), H311

Fire Suppression System

Water fire suppression is recommended for Diethyl Telluride

  • Water

    Water · Recommended

  • Dry Chemical

    Dry Chemical

  • CO₂ / Other

    CO₂ / Other

Guidance: Water fire suppression is generally recommended for Diethyl Telluride (C2H6Te). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.

Additional extinguishing notes: Water spray, alcohol resistant foam, dry chemical or CO2.

Always confirm extinguishing agents against the manufacturer SDS and your authority having jurisdiction before specifying a rental building fire-suppression package.

Storage & segregation guidance

Compliant storage and rental solutions for Diethyl Telluride should account for its listed hazards, climate control needs, and segregation requirements. Strong oxidizing agents.

Review NFPA 30 flammable liquid storage requirements and Fire-rated chemical storage rental when designing fire rating, containment, and building selection.

Properties: a) Appearance Form: liquid b) Odour No data available c) Odour Threshold No data available d) pH No data available e) Melting point/freezing point No data available f) Initial boiling point and boiling range 137 - 138 °C (279 - 280 °F) at 1,013 hPa (760 mmHg) g) Flash point 42 °C (108 °F) - closed cup h) Evaporation rate No data available i) Flammability (solid, gas) No data available j) Upper/lower flammability or explosive limits No data available k) Vapour pressure No data available l) Vapour density No data available m) Relative density 1.599 g/cm3 n) Water solubility No data available o) Partition coefficient: noctanol/water No data available

Matched to this chemical

Recommended storage solutions for Diethyl Telluride

Fire rating, footprint, and containment options from the US Hazmat Rentals fleet — sized for compliant chemical storage.

  • Fire-rated4 HourChemical Storage

    FireSAFE 4X

    • 4-Hour Fire-Rated
    • 8 ft x 40 ft
    • 57 Barrels
    • 55 Gal Storage Drums
    • 228 Square Feet storage
    View product
  • Fire-rated4 HourChemical Storage

    FireSAFE 4X

    • 4-Hour Fire-Rated
    • 8 ft x 10 ft
    • 12 Barrels
    • 55 Gal Storage Drums
    • 48 Square Feet storage
    View product
  • Fire-rated4 hourChemical Tote Storage

    Single Tote & Pallet Storage

    • 4-Hour Fire-Rated 6' Deep 1-Tote-Deep
    View product

Material handling

How do you manage your bulk chemical storage?

US Hazmat Rentals buildings are designed around the primary storage formats teams use in the field — each path opens the matching storage solution on ushazmatrentals.com.

We have solutions designed for your workflow process needs.

Frequently asked questions

How should Diethyl Telluride be stored?

Store Diethyl Telluride in EPA-, OSHA-, and NFPA-compliant containment suited to its hazards (Consult the SDS and applicable hazard classification). Climate range guidance: Follow the temperature range listed on the manufacturer SDS.. Compatibility notes: Strong oxidizing agents. US Hazmat Rentals provides compliant chemical storage buildings available for rental.

Is Diethyl Telluride flammable?

Yes — Diethyl Telluride is flagged as a flammable hazard in this database (Yes). Flash point: 42 C. Use fire-rated storage and follow NFPA 30 / applicable flammable-liquid rules where they apply.

What hazard class is Diethyl Telluride?

Diethyl Telluride is listed as: Consult the SDS and applicable hazard classification. Flammable liquids (Category 3), H226 Acute toxicity, Oral (Category 3), H301 Acute toxicity, Inhalation (Category 3), H331 Acute toxicity, Dermal (Category 3), H311

What fire suppression is recommended for Diethyl Telluride?

Water fire suppression is generally recommended for Diethyl Telluride (C2H6Te). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.

Is compliant Diethyl Telluride storage available for rent?

Yes. US Hazmat Rentals offers EPA-, OSHA-, and NFPA-compliant chemical storage buildings and containment that can be matched to Diethyl Telluride. Request sizing and compliance guidance at https://ushazmatrentals.com/chemical-storage-quote-request/.